| Design |
2 wheel hand cart, unitized with integrated component reservoirs for use with Kemko epoxy crack injection resins. |
| Materials of construction |
Welded all aluminum frame |
| Color |
Chemical resistant anodized aluminum case |
| Dimensions |
Height = 42", Width = 24", Length = 20" |
| Weight |
63 lbs dry weight |
| A Capacity |
2 gallons. |
| A Reservoir |
Inlet filter screen for foreign object control, sight glass for level
indication, float switch for empty reservoir detection and
automatic pump shutoff. |
| B Capacity |
1 gallon |
| B Reservoir |
Inlet filter screen for foreign object control, sight glass for level indication, float switch for empty reservoir detection and automatic pump shutoff |
| Power & Drive |
120 Vac, 3 Amps. Gear motor, 100 rpm, full load |
| Motor speed |
Variable, from 0 to 150 rpm, controlled by pressure transducer |
| Speed & Flow Control |
Automatic by pressure. Full rpm (150 rpm) and flow at zero p.s.i.
Slowing to stop (0 rpm) and no flow at 200 p.s.i. |
| Pump ON/OFF control |
Automatic pressure switch set by operator |
| Indicating light |
25 ft. of cord and indicating light, illuminated when pump is operating |
| A Pump |
Precision metering imported tool steel gear pump, 1.2 cc/rev. displacement |
| A Pump protection |
Final in-line filter on pump inlet |
| B Pump |
Precision metering imported tool steel gear pump, 0.6 cc/rev. displacement |
| B Pump protection |
Final in-line filter on pump inlet |
| Ratio |
2:1 by volume |
| Ratio accuracy |
+/- 2.5% error @ a 0.5 gallon/hour flow rate |
| Pumping pressure |
0 to 200 p.s.i. range |
| Pressure Control |
Automatic pressure switch set by operator. Switch programming eliminates surges |
| Delivery rate |
0 to 4.2 gallons of mixed adhesive per hour at 80 p.s.i. No load flow approximately 10 g.p.h. |
| Delivery hoses |
25 ft. in length, fuel resistant elastomer |
| Mix head |
Aluminum body with three tandem mix chambers containing replaceable mix elements
Fitted with operator control valve |
| Special features |
Integrated reservoirs, hose compartment, automatic pressure control, automatic pressure controlled pumping speed and flow rate (limits surges), reservoir low-level detection and shutoff, double filter protection of the component pumps, remote pumping 'on' indicating light, pump can be positioned and will function on its side for improved access into low openings |
 |